skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Search for: All records

Creators/Authors contains: "Spaulding, Reggie"

Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher. Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?

Some links on this page may take you to non-federal websites. Their policies may differ from this site.

  1. Ocean Acidification (OA) is negatively affecting the physiological processes of marine organisms, altering biogeochemical cycles, and changing chemical equilibria throughout the world’s oceans. It is difficult to measure pH broadly, in large part because accurate pH measurement technology is expensive, bulky, and requires technical training. Here, we present the development and evaluation of a hand-held, affordable, field-durable, and easy-to-use pH instrument, named the pHyter, which is controlled through a smartphone app. We determine the accuracy of pH measurements using the pHyter by comparison with benchtop spectrophotometric seawater pH measurements, measurement of a certified pH standard, and comparison with a proven in situ instrument, the iSAMI-pH. These results show a pHyter pH measurement accuracy of ±0.046 pH or better, which is on par with interlaboratory seawater pH measurement comparison experiments. We also demonstrate the pHyter’s ability to conduct both temporal and spatial studies of coastal ecosystems by presenting data from a coral reef and a bay, in which the pHyter was used from a kayak. These studies showcase the instrument’s portability, applicability, and potential to be used for community science, STEM education, and outreach, with the goal of empowering people around the world to measure pH in their own backyards. 
    more » « less
  2. null (Ed.)
  3. Abstract Total alkalinity (AT) is an important parameter in the study of aquatic biogeochemical cycles, chemical speciation modeling, and many other important fundamental and anthropogenic (e.g., industrial) processes. We know little about its short‐term variability, however, because studies are based on traditional bottle sampling typically with coarse temporal resolution. In this work, an autonomous ATsensor, named the Submersible Autonomous Moored Instrument for Alkalinity (SAMI‐alk), was tested for freshwater applications. A comprehensive evaluation was conducted in the laboratory using freshwater standards. The results demonstrated excellent precision and accuracy (± 0.1%–0.4%) over the ATrange from 800 to 3000 μmol L−1. The system had no drift over an 8 d test and also demonstrated limited sensitivity to variations in temperature and ionic strength. Three SAMI‐alks were deployed for 23 d in the Clark Fork River, Montana, with a suite of other sensors. Compared to discrete samples, in situ accuracy for the three instruments were within 10–20 μmol L−1(0.3–0.6%), indicating good performance considering the challenges of in situ measurements in a high sediment, high biofouling riverine environment with large and rapid changes in temperature. These data reveal the complex ATdynamics that are typically missed by coarse sampling. We observed ATdiel cycles as large as 60–80 μmol L−1, as well as a rapid change caused by a runoff event. Significant errors in inorganic carbon system modeling result if these short‐term variations are not considered. This study demonstrates both the feasibility of the technology and importance of high‐resolution ATmeasurements. 
    more » « less